DAQ VXI-SC-1102 User Manual

Browse online or download User Manual for Audio amplifiers DAQ VXI-SC-1102. DAQ VXI-SC-1102 User manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ComponentWorks
, CVI
, LabVIEW
, MITE
, NI-DAQ
, NI-VISA
, NI-VXI
, VirtualBench
, and VXIpc
are trademarks of National Instruments
Corporation. Product and company names are trademarks or trade names of their respective companies.
321519B-01
©
Copyright 1996, 1997 National Instruments Corp. All rights reserved. October 1997
U
SING
Y
OUR
NI-DAQ
S
OFTWARE
WITH
Y
OUR
VXI-DAQ
M
ODULE
Introduction
These notes describe your options when using NI-DAQ for PC
Compatibles version 5.1 or later with your VXI-data acquisition
(VXI-DAQ) module.
Note:
The information in these release notes applies only to configurations
using National Instruments VXIbus controllers.
NI-DAQ for PC Compatibles version 5.1 supports the following
VXI-DAQ products:
VXI-DIO-128
VXI-MIO-64XE-10
VXI-MIO-64E-1
VXI-AO-48XDC
VXI-SC-1000
VXI-SC-1102
VXI-SC-1150
on the following operating systems:
Windows 95
Windows NT 4.0
Page view 0
1 2 3 4 5 6 ... 21 22

Summary of Contents

Page 1 - Introduction

ComponentWorks ™, CVI ™, LabVIEW ™, MITE ™, NI-DAQ ™, NI-VISA ™, NI-VXI ™, VirtualBench ™, and VXIpc ™ are trademarks of National InstrumentsCorporati

Page 2 - Software Installation

108. If you get the message The device did not pass the test, check yourVXI-DAQ device settings.9. When finished testing your device, close the pa

Page 3 - VICTEXT. Type in the

11Configuring Your VXI-SC SubmoduleYou must run RESMAN before starting the NI-DAQ Configuration Utility.Write down the VXI logical address assigned to

Page 4

12Programming Your VXI-DAQ ModuleThis section provides an overview of the functions available forprogramming your VXI-DAQ modules. Additional informat

Page 5 - Configuration

13DIG_In_Port• When the software reads output ports, the returned data is simply thelast data written, and the returned status is the badChanDirError

Page 6 - VXIEDIT. Choose the Logical

14to the TTL level (1.5 V) whenever the NI-DAQ driver is loaded. Anychanges you make will endure only for the life of the program.Get_DAQ_Device_InfoI

Page 7

15VXI-AO-48XDC ModuleThe VXI-AO-48XDC programming model is very similar to theAO-2DC device. Any function or VI valid for the AO-2DC is also validfor

Page 8 - Embedded Controllers

16To repair your EEPROM, perform the following steps:a. Power down your chassis and remove your VXI-MIO boardfrom the system.b. Change switch S2 to

Page 9

17message, most likely it means that you failed to configure your VXIcontroller correctly.If you added additional memory to your VXI controller withou

Page 10

18operations in LabVIEW. The VXI-DIO-128 and theVXI-AO-48XDC do not require kernel mode access and arecompletely functional without it.7. How do I kno

Page 11

19making these changes in the NI-DAQ Configuration Utility, reset orpower cycle your VXIbus chassis, and run RESMAN.Next, set your LabVIEW application

Page 12 - LabWindows/CVI Functions

2Software InstallationA typical installation includes these National Instruments driver softwareproducts:• NI-VXI• NI-VISA• NI-DAQ for PC Compatibl

Page 13

2011. How do I use SCXI with my VXI-MIO module?Simply follow the procedures outlined in your NI-DAQdocumentation for MIO E Series devices. Using SCXI

Page 14 - LabVIEW VIs

21f. Select Update Current Configuration. After updating theEEPROM, return to the Logical Address ConfigurationEditor.g. Change the VXI Shared Ram S

Page 16

3♦ Windows NTLook for the NIVXIINT.DLL file in the\WINDOWS\SYSTEM32 directory. Right-click on the file andselect Properties in the menu. This will br

Page 17 - AI_VRead in

4If you do not find the program, perform the following steps:♦ Windows 95Look in the \WINDOWS\SYSTEM\ directory for theVISA32.DLL file. Right-click on

Page 18

5ConfigurationConfiguring Your VXIbus ControllerAfter you install all your software, run the following configurationprograms to configure your VXIbus

Page 19 - VXIDAQ.CFG

65. Click on Load.6. You should see a message that your Configuration RestoredSuccessfully.7. Select Update Current Configuration. After updating the

Page 20 - VXIEDIT

7Configuring PCI-MXI-2 Controllers♦ Using NI-VXI 1.5 and VXIEDIT1. Launch VXIEDIT.2. Choose the PCI-MXI-2 Configuration Editor.3. Select Load Configu

Page 21

8♦ Using NI-VXI 2.0 and Test & Measurement Explorer1. Launch Test & Measurement Explorer.2. In the System View window, right click on the PC

Page 22

9To configure your new VXI-DAQ device for use by NI-DAQ, performthe following steps:1. Run the NI-DAQ Configuration Utility.2. The utility should no

Comments to this Manuals