Overview and Applications
NI Full-Featured E Series devices are the fastest and the most accurate
multiplexed data acquisition devices available. They are ideal for
applications ranging from continuous high-speed data logging to
control applications to high voltage signal or sensor measurements
when used with NI signal conditioning. Synchronize the operations
of multiple devices using the RTSI bus or PXI trigger bus and easily
integrate other hardware such as motion control and machine vision
to create an entire measurement and control system.
Visit ni.com/oem for information on our
quantity discounts for OEM customers.
Highly Accurate Hardware Design
NI Full-Featured E Series DAQ devices includethe following features
and technologies:
Temperature Drift Protection Circuitry – Designed with components
that minimize the effect of temperature changes on measurements to
less than 0.0006% of reading per °C.
Resolution-Improvement Technologies – Carefully designed noise
floor maximizes resolution.
Onboard Self-Calibration – Precise voltage reference included
for calibration and measurement accuracy. Self-calibration is
completely software controlled, with no potentiometers to adjust.
NI DAQ-STC – Timing and control ASIC designed to provide more
flexibility, lower power consumption, and a higher immunity to noise
and jitter than off-the-shelf counter/timer chips.
• 16 or 64 analog inputs at up to
1.25 MS/s, 12 or 16-bit resolution
•2 analog outputs at up to 1 MS/s,
12 or 16-bit resolution
•8 digital I/O lines (TTL/CMOS);
two 24-bit counter/timers
•Analog and digital triggering
• 14 or 15 analog input signal ranges
• NI-DAQ driver simplifies
configuration and measurements
Families
• NI 6071E
• NI 6070E
• NI 6062E
• NI 6052E
• NI 6040E
• NI 6033E
• NI 6032E
• NI 6031E
• NI 6030E
• NI 6020E (only digital triggering)
Operating Systems
•Windows 2000/NT/XP
•Real-time performance with
LabVIEW (page 134)
•Others such as Linux and Mac OS X
(page 187)
Recommended Software
• LabVIEW
• LabWindows/CVI
•Measurement Studio
• VI Logger
Other Compatible Software
•Visual Basic, C/C++,and C#
Driver Software (included)
• NI-DAQ 7
Calibration Certificate Included
See page 21.
E Series – Full-Featured
Full-Featured E Series Multifunction DAQ
12 or 16-Bit, up to 1.25 MS/s, up to 64 Analog Inputs
199
National Instruments • T
el: (800) 433-3488
•
Fax: (512) 683-9300
•
[email protected] •
ni.com
Full-Featured E Series Multifunction DAQ
Data Acquisition and
Signal Conditioning
Analog Input Max Input Analog Output Output Output
Family Bus Inputs Resolution Sampling Rate Range Outputs Resolution Rate Range Digital I/O Counter/Timers Triggers
NI 6071E PCI, PXI 64 SE/32 DI 12 bits 1.25 MS/s ±0.05 to ±10 V 2 12 bits 1 MS/s ±10 V 8 2, 24-bit Analog, digital
NI 6070E PCI, PXI, FireWire 16 SE/8 DI 12 bits 1.25 MS/s ±0.05 to ±10 V 2 12 bits 1 MS/s ±10 V 8 2, 24-bit Analog, digital
NI 6062E PCMCIA 16 SE/8 DI 12 bits 500 kS/s ±0.05 to ±10 V 2 12 bits 850 kS/s ±10 V 8 2, 24-bit Analog, digital
NI 6052E PCI, PXI, FireWire 16 SE/8 DI 16 bits 333 kS/s ±0.05 to ±10 V 2 16 bits 333 kS/s ±10 V 8 2, 24-bit Analog, digital
NI 6040E PCI, PXI 16 SE/8 DI 12 bits 500 kS/s ±0.05 to ±10 V 2 12 bits 1 MS/s ±10 V 8 2, 24-bit Analog, digital
NI 6033E PCI 64 SE/32 DI 16 bits 100 kS/s ±0.1 to ±10 V 0 - - - 8 2, 24-bit Analog, digital
NI 6032E PCI 16 SE/8 DI 16 bits 100 kS/s ±0.1 to ±10 V 0 - - - 8 2, 24-bit Analog, digital
NI 6031E PCI, PXI 64 SE/32 DI 16 bits 100 kS/s ±0.1 to ±10 V 2 16 bits 100 kS/s ±10 V 8 2, 24-bit Analog, digital
NI 6030E PCI, PXI 16 SE/8 DI 16 bits 100 kS/s ±0.1 to ±10 V 2 16 bits 100 kS/s ±10 V 8 2, 24-bit
Analog, digital
NI 6020E NI USB 16 SE/8 DI 12 bits 100 kS/s ±0.05 to ±10 V 2 12 bits 20 S/s ±10 V 8 2, 24-bit
Digital
Table 1. NI Full-Featured E Series Model Guide (See page 228 for detailed specifications.)
Comments to this Manuals